PRE-INSTALLATION REQUIREMENTS
These vent hoods are heavy. Adequate structural support must be provided.
Actual length of straight duct plus duct fitting must equivalent. Equivalent
lengths of duct pieces are based on actual tests conducted by Evaluation
Engineering and reflect requirements for good venting performance with
any ventilation hood.
IMPORTANT
Plug the unit in and test all functions before installing.
Please read the instructions carefully. Unpack the Range Hood and check
that all functions are working before installing.
Ensure that the voltage (V) and the frequency (Hz) indicated on the sticker
match the voltage and frequency at the installation site.
Check that the area behind the installation surface to be drilled is clear of
any electrical cables or pipes, etc.
The stainless steel surfaces of the Range Hood are very easily damaged
during installation if scratched or bumped by tools. Please take care to
protect the surfaces during installation.
Protect the cooktop surface below with cardboard, or the like, to prevent
damage occurring during installation.
The manufacturer shall not be held liable for consumer’s failure to observe
and follow all pre-installation procedures and safety regulations.
The vertical distance from the cooking surface to the bottom of the range
hood should be at least 24 in. to 36 in. for best performance.
Determine if your installation will be top venting or back venting, and
ensure that the openings in the cabinet or wall are in the appropriate
locations and appropriate size.
If this is a new installation, choose the venting method that suits your needs.
Cut out openings for the damper and for power access in the cabinet
bottom or exterior wall, depending on the installation method chosen.
DUCKWORK PLANNING
These vent hoods are equipped for 8 in. round ductwork. This hood may be
vented vertically through upper cabinet or ceiling. A duct transition piece is
supplied for vertical exhaust. You may use elbows (sold separately) to vent
horizontally through the rear wall (duct not included with ductless models).
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the outdoors.
Use the shortest and straightest duct route possible. For satisfactory
performance, duct run should not exceed 12.5 ft. equivalent length for any
duct configurations.
Use metal ductwork only.
WALL FRAMING FOR ADEQUATE SUPPORT