User Manual

29 30
1) Unscrew the regulator cap with the wrench.
(See Figure 15)
2) This is how the retainer pin looks for
Natural Gas usage. (See Figure 16)
3) Remove the retainer pin. (See Figure 17)
4) Reverse the retainer pin and put back into
the regulator cap. This is how the regulator
pin looks for LP gas usage. (See Figure 18)
5) Screw the regulator cap back into the
regulator and re-attach the regulator to the
nipple and flare union. (See Figures 12 and
19)
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
B. CHANGE BURNER NOZZLES
INSTALLATION TIP: First remove all nozzles and then start replacing them. This will help to prevent
the possibility that some may not be replaced.
1) Remove the burner grates, burner caps and burner heads.
2) Using a 7mm nut driver, remove the burner nozzles.
LIQUID PRETROLEUM (LP) GAS NOZZLES
BURNER POSITION NOZZLE
DIAMETER
MINIMUM
PRESSURE
MAXIMUM
PRESSURE
Auxiliary Front Right 1 x 0.70 10” 14”
Semi-Rapid Rear Left & Right 1 x 0.80 10” 14”
Rapid Front Left 1 x 0.89 10” 14”
Triple Ring Center 5 x 0.56 14”
IMPORTANT: Carefully read and observe each nozzle label for correct location.
3) Install the proper nozzles in the exact locations as noted in the illustrations above and the
table below. (See Figures 20, 21 and table above)
4) Replace the burner bases, heads, caps and top grates. Make sure burner caps are properly
seated on the burner head.
Figure 20
TRIPLE RING BURNER
5 NOZZLES
AUXILARY BURNER
SEMI-RAPID BURNER
RAPID BURNER
1 NOZZLE EACH
NOZZLES
Figure 21
10”