WARNING
Electrical Shock Hazard
12
STEP 3 - MAKE ELECTRICAL CONNECTION
After reading the requirements for each Electrical Connection method, follow
the instructions specific to your situation.
POWER CORD - U.S.A. ONLY
Disconnect power before servicing.
Use a new 50 amp UL listed or CSA certified power supply
cord. Plug into a grounded outlet.
Do not use an extension cord.
Failure to do so can result in death, fire, or electrical shock.
3-WIRE CONNECTION: POWER SUPPLY CORD
IMPORTANT: Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1
. Disconnect power.
2
. Remove the access panel located on the bottom right-hand side of the
back panel to uncover the electrical terminal block.
a
b
c
a Access Panel to Electrical
Supply Connection
b Power Cord Opening
c Recessed Area
Installation Instructions
13
3. Install a UL listed strain relief (not provided) to the power cord opening in
the bracket, and then completely tighten the strain relief nut.
4
. Thread the end of the power cord through the strain relief.
N
OTE: Allow enough slack to connect the wires to the terminal
block.
c
a UL Listed Strain Relief
a
b Power Cord
b
c Jumper Wire
5
. Using a 5/16" nut driver and one of the -0-32 hex nuts, connect the neutral
(white) wire from the power cord to the center terminal block post along with
the green jumper wire from the range.
6
. Using 10-32 hex nuts, connect the red and black wires from the power cord
to the outer posts of the terminal block with the corresponding red and
black wires from the range.
7
. Tighten the hex nuts completely, and then verify the connection.
N
OTE: For power supply cord replacement, use only a power cord rated
at 250volts minimum, 50-amps that is marked for use with nominal 1 3/8"
(3.5cm) diameter connection opening, with ring terminals and marked for
use with ranges.
8
. Position the lower part of the strain relief under the power cord and tighten
the strain relief screws.
N
OTE: Before tightening, make sure the strain relief is positioned over the
cord and NOT the wires.
9
. Replace the electrical access panel.
1
0. Plug range into grounded outlet.
1
1. Tuck excess power cord into the recessed area of the back panel.