Installation Manual

15
ELECTRICAL REQUIREMENTS - CANADA ONLY
Be sure that the electrical connection and wire size are adequate and in
conformance with the CSA Standard C22.1, Canadian Electrical Code, Part 1 -
latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Electrical Connection
Check local codes and consult gas supplier. Check existing electrical supply
and gas supply. It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.
Check with a qualified electrical installer if you are not sure the range is
properly grounded.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified Power Cord
intended to be plugged into a standard 14-50R wall receptacle. Be sure the
wall receptacle is within reach of range's final location.
Do not use an extension cord.
The wiring diagram is located on the back of the range in a clear plastic
bag.
NOTE: The metal chassis of the range must be grounded in order for the
control panel to work. If the metal chassis of the range is not grounded, no
keypads will operate. Check with a qualified electrician if you are in doubt as
to whether the metal chassis of the range is grounded.