Installation Manual

16
GAS SUPPLY REQUIREMENTS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does
not exceed 14" (36 cm) water column.
Examples of a qualified person include:
Failure to do so can result in death, explosion or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must conform with
American National Standard, National Fuel Gas Code ANSI Z223.1 - latest
edition or CAN/CGA B149 - latest edition.
IMPORTANT: Leak testing of the range must be conducted according to the
manufacturer's instructions.
TYPE OF GAS
Natural Gas:
This range is design-certified by CSA International for use with natural gas or,
after proper conversion, for use with LP gas.
This range is factory-set for use with Natural gas. The model/serial rating
plate located on the right side oven door trim has information on the types
of gas that can be used. If the types of gas listed do not include the type of
gas available, check with the local gas supplier.
licensed heating personnel
authorized gas company personnel
authorized service personnel