Installation Manual

33
7. Screw and tighten the regulator cap back into the gas pressure regulator
with the wrench.
Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove the burner grates, burner caps, and the burner base.
3. Remove the natural gas orifices with a 9/32" (7 mm) nut driver.
4. Replace the natural gas orifices with the correct LP gas orifices from the LP
conversion kits. LP gas orifices are stamped with a size. Refer to the
following chart for correct LP gas orifice ratings and sizes for proper
placement.
Regulator
Cap
Orifice
Orifice Size
(091 - Denotes 0.91 mm)
091