Grounding
• The power cord is equipped with a three-prong (grounding) plug which mates with a
standard three-prong grounding wall receptacle to minimize the possibility of electrical
shock hazard from the range.
• All cord connected appliance shall include instructions relative to location of the wall
receptacle and a warning to the user to disconnect the electrical supply before
serving the appliance.
• Where a standard two-prong wall receptacle is encountered, it is the responsibility and
obligation of the customer to have it replaced with a properly grounded three-prong
wall receptacle. Do not cut or remove the grounding prong from the power cord.
Connect Range to Gas Supply
• Install a manual gas line shut-off valve in the gas line in an easily accessed location
outside the range in the gas piping external to the appliance for the purpose of turning
on or shutting off gas to the appliance.
• Install male ½” flare union adapter to ½” NPT internal thread elbow at inlet of regulator.
On models equipped with standard twin burners, install the male pipe thread end of
the ½” flare union adapter to the ½” NPT internal thread at inlet of pressure regulator.
Use a wrench on the regulator fitting to avoid damage.
• Install male ½” or ¾” flare union adapter to the NPT internal thread of the manual shut-
off valve, taking care to secure the shut-off valve to keep it from turning.
• The gas supply pressure for checking the regulator setting is 6in (Natural Gas) and
11inch (LP gas) connect flexible gas line connector to the regulator on the range.
Position range to permit connection at the shut-off valve.
• When all connections have been made, check that all range controls are in the “off”
position and turn on the main gas supply valve.
Leak testing of the appliance shall be conducted according to the manufacture’s
instructions. Use some soap water (50% water and 50% soap) or a leak detector at all
joints and connections to check for leaks in the system. Do not use a flame to check
for gas leaks.
• The appliance must be isolated from the building’s gas supply piping system by closing
its individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressure equal to or less than ½ psig (3.5kPa).
INSTALLATION INSTRUCTIONS
17