Installation Guide

15
3-3. Charging Status LED Indicator
Charging status LED Status
Bulk-1 Orange fast
Bulk-2 Orange slow
Absorption-1 Orange solid
Absorption-2 Green solid
Float
Green flash
LED color change by the status change
3-4. Failure Indicator
Failure status LED Status Description
Input or
Output
Red solid
Output current is reduced to <1A
AC I/P unstable
Output FUSE blown
Temperature Red fast
Battery over heat (the indicator is
available only when COTEK
temperature sensor is connected)
Battery under heat (the indicator is
available only when COTEK
temperature sensor is connected)
Charger over heat (Heat Sink)
Battery
voltage
Red slow
Battery over voltage
Battery under voltage or output
under voltage in C.C. mode.
Fan
abnormality
Red light
flash twice
Fan abnormality
ESB Failure
Red slow
every 2 sec.
ESB no output / output short