Installation Guide

4
2-1.Battery Charging Curve
14.4 / 28.8 V
13.8 / 27.6 V
12.8 / 25.6 V
9.6 / 19.2 V
0V
Current
Charging stage
BULK(CC)PER-CHARGE ABSORPTION(CV) FLOAT RECONDITION
Voltage
Return amps = 6.25% of rated current
Reduce charging time
by charging at maximum
current
(Constant current mode)
---
---
Make sure the battery is fully
charged without overcharging
(Constant voltage mode)
Maintain the
battery at
100% charge
condition
Reconditioning the
battery
14.4V / 28.8V with
rated current
Stay at
13.8V / 27.6V
14.4V / 28.8V until the current
drops to 6.25% of rated current
Charging at rated current
Charging spec
BULK
2 min~8 hours
ABSORPTION
0.25 hours~24 hours
FLOAT
2 Weeks
RECONDITION
85 min
BULK(CC)
Once battery voltage
is below 12.8/25.6V,
after 30 seconds, CX
will turn from FLOAT
to BULK
BULK
2 min~8 hours
FLOAT
Maintain the
battery at
100% charge
condition
Stay at
13.8V / 27.6V
FLOAT
2 Weeks