SE350 User Manual

50
FR
4-5-2. SE350
V
Tension haute (DC)
Alarme tension
basse
Tension basse
Coupure
Reprise
Coupure
Reprise
12V
15.5V ± 0.25V
14.5V± 0.25V
10.5V ± 0.25V
10V ± 0.25V
12V± 0.25V
24V
31V ± 0.5V
29V ± 0.5V
21V± 0.5V
20V ± 0.5V
24V ± 0.5V
48V
62 ± 1V
58V ± 1V
42V± 1V
40V ± 1V
48 ± 1V
Tableau 22. SE350 Protections entrée CC
V
Protection surchauffe
Coupure
Reprise
12V
83°C ± 5°C
53°C ± 5°C
24V
48V
Tableau 23. SE350 Protection surchauffe
4-5-3. SE400
V
Tension haute (DC)
Alarme tension
basse
Tension basse
Coupure
Reprise
Coupure
Reprise
12V
16V ± 0.3V
14.5V± 0.3V
10.5V ± 0.3V
10.5V ± 0.3V
12.5V± 0.3V
24V
32V ± 0.5V
29V ± 0.5V
21V± 0.5V
21V ± 0.5V
25V ± 0.5V
48V
64 ± 1V
58V ± 1V
42V± 1V
42V ± 1V
50 ± 1V
Tableau 24. SE400 Protections entrée CC
V
Protection surchauffe
Coupure
Reprise
12V
80°C
60°C
24V
48V
Tableau 25. SE400 Protection surchauffe