SL2000-112 Manual

16
4-1-7. Charger Setting for various battery types
The following table gives the Absorption, Float and Equalization voltage settings for batteries commonly used
Battery Type
Inverter
Voltage
Absorption
Voltage
Float
Voltage
Equalization
Voltage
Gel
12 VDC
14.1VDC
13.6VDC
NOTE!
Flooded
14.6VDC
13.4VDC
15.5VDC
AGM 1
14.3VDC
13.1VDC
15.5VDC
AGM 2
14.5VDC
13.5VDC
NOTE!
Custom*
12~16VDC
12~16VDC
12~16VDC
*User can be setting the custom function voltage, but must use LCD remote control or
RS-232 (See chapter“6” for more information).
Table 4
Various battery type charging setting
NOTE
Gel and the AGM 2 Group (East Penn / Deka / Discover / Trojan brand) batteries are not equalized.
Hence, their Equalization Voltages are same as the Absorption Voltages.
WARNING!
When using the Custom setting, the Equalization voltage setting should not allow voltage lower than
the Absorption Voltage setting. Also, the Equalization Voltage setting should not allow a setting
higher than 2-volts (for 12V systems) above the Absorb Voltage setting.
4-2. Operation mode introduction
There are four Operation mode : 1.Basic 2.Charger 3.Power sharing 4.Generator operation modes.
4-2-1. Basic Mode
When there is no external “AC input” power available, the inverter of the unit provides AC power output load
from the batteries. There is no AC power available on the “AC output load”. See Fig. 12.
Fig. 12
Basic mode