SL2000-112 Manual

2
vii) Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a
lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to weld a ring or the
like to metal, causing a severe burn.
viii) NEVER charge a frozen battery.
ix) If necessary to remove battery from vessel, always remove grounded terminal from battery first. Make
sure all accessories in the vessels are off, so as not to cause an arc.
x) Be sure area around battery is well ventilated.
xi) Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
xii) Study all battery manufacturers specific precautions such as removing or not removing cell caps while
charging and recommended rates of charge.
xiii) Add distilled water in each cell until battery acid reaches level specified by battery manufacturer. This
helps purge excessive gas from cells. Do not overfill. For a battery without cell caps, carefully follow
manufacturers recharging instructions.
1-3. Other Safety Notes
DC CONNECTION PRECAUTIONS
Connect and disconnect DC output connections only after setting the power unit switches to off position
and removing AC cord from electric outlet or opening AC disconnect.
GROUNDING INSTRUCTIONS This power unit should be connected to a grounded, metal, permanent
wiring system; or an equipment-grounding conductor should be run with circuit conductors and connected
to equipment-grounding terminal or lead on unit. Connections to unit should comply with all local codes
and ordinances.
Upon receipt, examine the carton box for damage. If you have found any damage on the carton box please
notify the company you purchased this unit from.
Do not operate near water or in excessive humidity.
Do not open or disassemble the inverter, and warranty may be voided.
The DC side connections should be firm and tight.
Install the inverter in a well-ventilated area. Do not block the front air vents, or the rear air exhausts of the
unit.
Wiring: Adequate input power must be supplied to the inverter for proper use; correct wiring sizes must be
ensured.
Do not operate appliances that may feed power back into the inverter.
Temperature: The inverter should be operated in an ambient temperature range of -20 to 40 otherwise