into fault mode when the PV power generation system fails.
Check the fault information on the LCD, which may be
referred to “6.3.4 Present fault” and “6.3.5 History”. Specific
cause can also be found in “5.3 Troubleshooting” and
corresponding instructions are available to eliminate the
faults.
Figure 5-9 Fault indication interface
5.3 Troubleshooting
There are mainly three fault alert statuses: Warn,
Protect and Fault. When there is a “Warn”, the system only
reminds customers of the problem while it doesn’t change
the operation mode. When there is a “Protect”, the system
will turn into fault mode and come back to normal when the
“Protect” disappears. When there is a “Fault”, the system will
stop working and remain standby until resetting the system
or repair the inverter to eliminate the fault.
Two ways of system reset are listed as follows:
1. Turn off the AC circuit breaker, wait for 5 seconds and
turn on the AC circuit breaker again to recharge the system
control unit. If the system check is passed, the inverter will
turn into normal operation mode.