Warn/Protect/
Fault
Definition Possible causes
Recommended
solutions
4Contact after-sale
service personnel
5PV.Reverse
PV panel is
connected
reversely
1PV positive pole
and negative pole
are connected
reversely;
1Check whether
positive pole and
negative pole are
connected reversely;
2Contact after-sales
service personnel
6AC.ContErr
AC contactor has
abnormality
1AC contactor is
damaged;
2Power supply
circuit of the
contactor has
problem
Contact after-sale
service personnel
7EmergencyStp
Inverter is in the
status of
emergent stop
Emergency stop
button is pressed
1Check whether
emergency stop button
is pressed. If so, restore
the button;
2Contact after-sale
service personnel if the
problem still exists
8GFCI.Err
PV grounding
fault
1Excessive
current passes
through return
circuit in the result
of disconnecting
internal PV
grounding
1Check whether the
system has ground
connection or
grounding fault;
2Check whether the
LED on GFDI is lighted
on. If so, replace with a
new fuse;
3Contact after-sales
service
personnel