Cortana Ceiling Fan CR52 Installation Instructions Instrucciones de instalación Instructions d’installation
1 Read and Save These Safety Precautions 1. Turn off electricity at main switch before wiring or servicing fan in order to avoid possible electrical shock. 2. All wiring must be in accordance with the National Electric Code (ANSI/NFPA70-1999) and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3.
2 Before Assembly 1. Make sure that the fan voltage (120) is compatible with your own electrical system. 2. Check to make sure that your carton contains all the parts mentioned in the parts list. NOTE: The box can be used as a work space to prevent any damage on the ornamental surface. CAUTION: Before installing, choose a location for mounting the fan where the blades have at least 7 feet of clearance from all objects and floor. Mount an outlet box to the ceiling or use an existing box.
3 Turn off circuit breakers and wall switch to the fan supply line leads. Preparation Important: When using an existing outlet box, be sure the box is securely attached to the building structure and can support the full weight of the fan. Failure to do so can result in serious injury or death. b.) Angle Mount 7BVMUFE $FJMJOHT B %PXOSPE .PVOU /PSNBM $FJMJOHT IMPORTANT: If using the angle mount method, check to make sure the ceiling angle is not steeper than 35º.
4 Installing Mounting Bracket Support Beam “J” Hook (S7) Outlet Box (A) Ceiling OUTLET BOX Mounting Bracket (1) Bracket Screws & Washers (S2) Wood Screws (S1) Wood Screws (S1) NOTE: Do not mount directly to sheet rock or ceiling tile. Prior to securing mounting bracket, screw "J" hook (S6) into ceiling outlet box as a secondary support means. Secure mounting bracket (#1) to the outlet box (A) by tightening bracket screws & washers (S2) as shown.
5 Downrod Assembly Locate downrod assembly (#2). Loosen ball screw on black hanging ball to free lock pin. Black hanging ball will slide down. Remove ground screw and green ground wire. Remove hanging ball from downrod and save all parts. Insert fan wires through downrod.
6 Thread the downrod onto the motor housing making sure the wires don’t get twisted. Insert saftey bolt (S6) through flange & downrod and attach nut. Tighten firmly. Tighten set screw against downrod.
7 Place Flange Cover (7), Downrod Accessory Distributor (6), Upper Distributor Cover (5), Canopy Cover (4) and Canopy (3) over downrod assembly. Align and insert Decorative Screws (10) through Downrod Accessory arm (9) with the holes of the distributor. Align screws on lower downrod accessory arm with slots in the top of the fan housing (8). Tighten all screws securely. WARNING: Failure to completely tighten downrod as described in steps above could result in the fan loosening and possibly falling.
8 Lift fan onto the mounting bracket (#1). Turn housing until hanging ball seats itself into ball socket (listen for click). For added security, attach safety cable from fan unit to "J" hook (S7) in outlet box. Secure by looping zip tie (S8) through safety cable and "J" hook. Tighten zip tie securely. WARNING: To reduce the risk of fire, electric shock or personal injury, mount so outlet box marked "acceptable for fan support" and use mounting screws provided with the outlet box.
9 Ground White (Neutral) Wire Connectors (S6) Black (Power) White Ground (Green) Black Outlet Box Ground (Green) 1. Connect fan wires to ceiling wires: white fan wire to white outlet wire, black to black. Wire connectors (S6 ) are provided for your convenience. 2. After connections are made, turn splices upward and push carefully into outlet box. Separate black wires on one side of the box, and white wires on the other side.
10 Loosen two screws from the hanger bracket. Align the canopy up to ceiling and over the loosened screws. Place the canopy into the keyhole and rotate canopy clockwise. Secure the canopy by tightening the previous loosened screws. Rotate the canopy cover clockwise. Attach the blades to the blade arms by using three blade screws (S3) and paper washers. Tighten securely. Remove rubber shippiing grommets before attaching blade assembly.
11 Install the three 50W bulbs. (Included) Take care not to touch bulb with bare fingers. Wipe bulb with clean cloth to remove oily residue. Remove two set screws on the mounting ring, align the keyholes of the mounting plate and the Switch Cap Mounting Plate, attach two screws previously removed and tighten screws securely. Align the switch cap to the switch cap mounting plate and tighten by twisting the finial.
Remote Control Operation Instructions ON/OFF For emergency shut off. SPEED CONTROL Controls fan motor speed. To select desired speed, press button once and release. REVERSE Controls direction of fan blades. To reverse fan blades, press once and release. FAN OFF or STOP Turns fan motor speed off. Press once to turn off. To start motor speed again, hit one of the motor speed buttons. L-1 or UPLIGHT Controls the on/off and intensity* for integrated light kit. Push and release for on/off function.
IMPORTANT! PLEASE READ: All Craftmade Ceiling Fans are prepared with a durable lacquer or a painted finish. Your proper care will enhance both the life and appearance. Post treatments, such as clear lacquer, are not recommended. PROPER CARE In order to maximize the appearance of your Craftmade ceiling fan, it is important that dust and debris is removed from the surface periodically.