Manual

PROBLEM
Engineisrunning,butno
ACoutputisavailable.
Enginerunsgoodat no-loadbut "bogs
down"whenloadsareconnected.
Enginewillnotstart;orstarts
andrunsrough.
Engineshutsdown duringoperation.
Enginelackspower.
Engine"hunts"or falters.
CAUSE
1. Oneofthe circuitbreakersis open.
2. Faultingenerator.
3. Poorconnectionor defectivecordset.
4. Connecteddeviceis bad.
.
2.
3.
CORRECTION
1. Resetcircuitbreaker.
2. ContactSearsservicefacility.
3. Checkandrepair.
4. Connectanotherdevicethatis ingood
condition.
Shortcircuitina connectedload. 1.
Enginespeedistoo slow. 2.
Generatoris overloaded. 3.
.
4. Shortedgeneratorcircuit.
1. Run/StopSwitchsetto "Stop".
2. Dirtyaircleaner.
3. Outof gasoline.
4. Stalegasoline.
5. Sparkplugwire notconnected
to sparkplug.
6. Badsparkplug.
7. Waterin gasoline.
8. Overchoking.
9. Lowoil level.
10.Excessivelyrichfuel mixture.
11.Intakevalvestuckopenorclosed.
12.Enginehaslostcompression.
1. Outof gasoline.
2. Lowoil level.
I. Loadistoo high.
2. Dirtyairfilter.
1. Chokeis openedtoo soon.
2. Carburetorisrunningtoo rich
ortoo lean.
Disconnectshortedelectricalload.
ContactSearsservicefacility.
See"Don'tOverloadthe Generator",
page8.
ContactSearsservicefacility.
1. Setswitchto "Run".
2. Cleanor replaceaircleaner.
3. Fillfueltank.
4. Draingas tank;fill withfreshfuel.
5. Connectwireto sparkplug.
6. Replacesparkplug.
7. Draingas tank;fill withfreshfuel.
8. Openchokefullyandcrankengine.
9. Fillcrankcaseto properlevel.
10. ContactSearsservicefacility.
11. ContactSearsservicefacility.
12. ContactSearsservicefacility.
1. Fillfueltank.
2. Fillcrankcaseto properlevel.
1. See"Don'tOverloadthe Generator"on
page8.
2. Replaceairfilter.
1. Movechoketo halfwaypositionuntil
enginerunssmoothly.
2. ContactSearsservicefacility.