Manual

Table Of Contents
page 32 of 720
BIOREMEDIATING parts washing system
SmartWasher
®
USER INSTRUCTION MANUAL
ORIGINAL INSTRUCTIONS
ISSUE REMEDIAL ACTION
Excessive fluid
loss
With “normal usage” you should have to add a 20 liter container of OzzyJuice
®
approximately
every 6 to 8 weeks. “Normal usage” means the equivalent of several users in a 10 hour day
in a standard maintenance, repair and operation facility or several users in a multiple bay
garage facility.
a) Check the fluid temperature. If the temperature is above 49°C the probe is not working
properly. Temperatures above 49°C will increase the rate of evaporation.
b) Examine closely where the sink and base meet. Are there any gaps? Is the base bowed? Is
the sink warped? The SmartWasher operates as a closed system; any gaps will provide
space for air to enter and condensation to escape.
Is the SmartWasher
®
“leaking”? Where is it “leaking” from?
Make sure the nozzle and brush are flowing into the sink.
If the fluid is leaking from the body of the base?
The base will need to be replaced.
If none of the previous applies, this rules out any problem with the SmartWasher
®
itself.
Make sure you and your co-workers are aware that certain practices can cause you to use
excessive amounts of OzzyJuice
®
.
Low or no flu-
id from brush/
nozzle
Make sure that the valves at the base of the nozzle and brush are open.
If a stronger flow through either device is needed, turn the valve on the unused tool to the
closed position
Hoses from the pump to the nozzle and brush could be clogged, pinched or disconnected.
Check the hoses from the pump to the nozzle making sure they are in working order.
Make sure that the SmartWasher
®
is not low on fluid
Hose connections should be secure and not leaking
The pump becomes with a one year factory warranty. If the pump is faulty, contact your local
CRC distributor to order your warranty replacement (if applicable). Have the serial number
of the SmartWasher
®
unit available when calling.