Synchronization
Auto Synchronization
Z-Link
ADAT inputs may operate in an arbitrary phase relationship to the device Word
Clock. In addition, each device may have a different phase offset.
In order to ensure that groups A and B are played back correctly in-phase, the
start of every receivedADAT signal must be offset by no more than of a
Word Clock period with respect to the reference clock (internal or sync
source). If the phase difference is larger than this, the signal will nevertheless
still be correctly received, but may be shifted by one sample.
+/- 25%
For proper operation of SonicCore boards we
therefore took care, that all ADAT outputs are
correctly phased anytime- even those of multicard
systems!
Whenever a signal is present on the ADAT A or Z-Link A interface, the
will synchronize itself to this signal, regardIess of whether a signal is also
present on interface B. When a signal is present on interface B and no signal is
detected on interfaceA, the will synchronize itself to the interface
A16
Ultra
A16 Ultra
If only one Z-Link interface is connected, the other half of the converter
remains in ADAT mode. Since the converter always derives its sync clock from
the Z-Link data stream when in Z-Link mode, any device which is connected to
theADAT interface must be operated as a sync slave.
The Z-Link connectors must be driven by phase-aligned signals.
10
Analogconnectors
PowerSupply
In a DAW-system composed of multiple S/TDM-
interconnected Scope boards inside a single
computer, the correct phase alignment of the Z-
Link signals is managed automatically.
If the two Z-Link streams are not properly phase-aligned, the mutes
itself completely.
A16 Ultra
The stereo phone jacks of the analog inputs and outputs are connected as
follows:
(see the table 'Inputs and Outputs' on the next page)
Tip is hot (+), ring is cold (-)
The is delivered with the proper AC power adaptor and should be
used exclusively with this adapter.
In case of loss or damage please use only an 12 VAC 1.5A Power supply in
connection with your .
A16 Ultra
A16 Ultra
The signals that the is ready for operation. If this
LED does not light, check whether the AC adaptor is being supplied with
power. The contains no internal user-replaceable fuses. It is
protected internally against thermal and electrical overloading and shuts itself
down automatically when necessary to avoid damage. When the problem has
been solved, the will automatically switch itself on again.
green Power LED A16 Ultra
A16 Ultra