Specifications

Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless
testing requires power.
© 2005 Maytag Services 16026784 11
Problem Possible Cause Correction
Surface element does not
heat
Open element .................................................
Loose wire connection or broken wire ............
Failed infinite switch........................................
Check element for continuity,
replace if failed.
Verify all connections are clean
and tight, replace broken wiring.
Check infinite switch, replace if
failed.
Frequent cycling of surface
element or warming zone
Normal ............................................................
Element cycles to maintain
proper heat and to prevent
damage to smoothtop.