Problem Possible Cause Correction
Surface element does not
heat
Open element .................................................
Loose wire connection or broken wire ............
Failed infinite switch........................................
• Check element for continuity,
replace if failed.
• Verify all connections are clean
and tight, replace broken wiring.
• Check infinite switch, replace if
failed.
Frequent cycling of surface
element or warming zone
Normal ............................................................
• Element cycles to maintain
proper heat and to prevent