Specifications

Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
14 16026784 © 2005 Maytag Services
Illustration Component Test Procedure Results
Coil element, 4-turn
1500 W
(select models)
Disconnect wire leads to element and
measure resistance of terminals ............
Measure voltage at coil element.............
Approximately 35.5 to 39.1
.
240 VAC, see wiring diagram for
terminal identification. If voltage is not
present at element, check wiring.
Coil element, 5-turn
2350 W
(select models)
Disconnect wire leads to element and
measure resistance of terminals ............
Measure voltage at coil element.............
Approximately 22.6 to 25
.
240 VAC, see wiring diagram for
terminal identification. If voltage is not
present at element, check wiring.
Coil element, 4-turn
1250 W
(select models)
Disconnect wire leads to element and
measure resistance of terminals ............
Measure voltage at coil element.............
Approximately 42.4 to 47
.
240 VAC, see wiring diagram for
terminal identification. If voltage is not
present at element, check wiring.
Coil element, 5-turn
2100 W
(select models)
Disconnect wire leads to element and
measure resistance of terminals ............
Measure voltage at coil element.............
Approximately 25.3 to 27.9
.
240 VAC, see wiring diagram for
terminal identification. If voltage is not
present at element, check wiring.
Ribbon element,
1200W
(select models)
Disconnect wire leads to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approximately 44.3 to 48.9
.
240 VAC. If voltage is not present,
check wiring.
Ribbon element, dual,
2400W
Inner: .....1100W
Outer:....1300W
(select models)
Disconnect wire leads to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Inner: ...Approximately 51
.
Outer: ..Approximately 43
.
240 VAC. If voltage is not present,
check wiring.
Ribbon element,
2500W
(select models)
Disconnect wire leads to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approximately 21.3 to 23.5
.
240 VAC. If voltage is not present,
check wiring.
Ribbon element,
ceramas, 2700W
(select models)
Disconnect wire leads to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approximately 19.4 to 22
.
240 VAC. If voltage is not present,
check wiring.
Ribbon element,
ceran, 100W
(select models)
Disconnect wire leads to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approximately 133.3 to 147.3
.
240 VAC. If voltage is not present,
check wiring.
Ribbon element,
ceramas, 2700W
(select models)
Disconnect wire leads to element and
measure cold resistance of terminals.....
Measure voltage at element...................
Approximately 19.4 to 22
.
240 VAC. If voltage is not present,
check wiring.
Coil element, 3-turn
1250 W
(select models)
Disconnect wire leads to element and
measure resistance of terminals ............
Measure voltage at coil element.............
Approximately 42.5 to 46.9
.
240 VAC, see wiring diagram for
terminal identification. If voltage is not
present at element, check wiring.
Coil element, 4-turn
2100 W
(select models)
Disconnect wire leads to element and
measure resistance of terminals ............
Measure voltage at coil element.............
Approximately 33 to 38
.
240 VAC, see wiring diagram for
terminal identification. If voltage is not
present at element, check wiring.