Operation Manual
2.8 Remote Volume Control
You can remote-control the output volume of the 140MPA. To do so,
locate the OUTPUT VCA connector on the back panel. Insert a 4-pin
Phoenix-type cable connector into the OUTPUT VCA connector. Wire a
Crown 1-VCAP level control to the Phoenix-type cable connector ter-
minals as shown in Figure 2.12.
Figure 2.12 Wiring a 1-VCAP Level Control
to the Output VCA Connector
Phoenix-type
plug
Output VCA Connector
Output VCA Connector