User's Manual

DriveCore Install Network Series Power Amplifiers
page 65
Operation Manual
AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on all channels driven.
DCi 8|600N - Bridge
15004563770 120 VAC / 60 Hz 230 VAC / 50 Hz
Condition Load
"Line
current
(amps)"
Power Dissipated as Heat "Line
current
(amps)"
Power Dissipated as Heat
watts BTU kcal/hr watts BTU kcal/hr
At Idle Awake N/A 1. 9 218 744 188 1. 0 220 751 189
1/8 Power
Pink Noise
Typical of program
material just at clip
5.4 330 112 6 284 2.8 325 110 9 279
8.1 346 118 1 298 4.2 335 114 4 288
16Ω 7. 7 306 1044 263 3.8 276 941 237
140V (16Ω) 7. 7 300 1023 258 3.9 285 973 245
200V (33.33Ω) 7. 5 281 960 242 3.9 272 929 234
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
10.8 468 1597 403 5.4 445 1519 383
1 7. 9 530 1810 456 9.0 476 1625 410
16Ω 1 7. 0 421 1437 362 8.7 389 1328 335
140V (16Ω) 1 7. 3 439 1500 378 8.8 382 1305 329
200V (33.33Ω) 1 7. 0 412 1407 355 8.6 342 116 8 294
DCi 8600N - Dual
15004563770 120 VAC / 60 Hz 230 VAC / 50 Hz
Condition Load
"Line
current
(amps)"
Power Dissipated as Heat "Line
current
(amps)"
Power Dissipated as Heat
watts BTU kcal/hr watts BTU kcal/hr
At Idle Awake N/A 1. 9 222 756 191 1. 0 221 754 190
1/8 Power
Pink Noise
Typical of program
material just at clip
5.5 336 114 7 298 3.0 332 113 3 286
8.2 363 1241 313 4.4 348 118 6 299
7. 8 314 1071 270 4.1 293 999 252
70V (16.33Ω) 7. 6 307 1047 264 4.0 289 979 274
100V (33.33Ω) 7. 8 293 1001 252 3.9 262 896 226
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
11. 0 498 1700 429 5.9 476 1625 410
1 7. 5 510 1739 438 10.0 547 1868 471
1 7. 4 467 1593 402 9.1 421 1437 362
70V (16.33Ω) 1 7. 0 446 1522 384 9.0 393 1342 338
100V (33.33Ω) 16.8 419 1430 360 8.9 362 1234 3 11