Lock (Auto Level Threshold)—locks output Channel 1 and 2 so that changes to the Auto Level threshold of one
also affect the other
AMB-5 Mixer (includes all MPX-6 commands plus):
ASA—turn on/off all automation functions
Max Gain Tracks Control Block—makes Max Gain of each input equal to the control block gain settings
Control Block Override—this control is reserved for future use
Max Gain—set the maximum gain for an input of Channel 1
Low Set—set the “closed gate” gain for an input of Channel 1
Gate Algo—turn on/off the Gate function
Gate Threshold—set the point when an input gate “opens”
Duck Priority—turn on/off the Duck Priority function
Input Compression—turn on/off the Input Compressor/Limiter function
Input Compression Threshold—set the point when input compression begins
Auto Level—turn on/off the Auto Level function
Auto Level DAOL—set the Desired Average Output Level of each input of Channel 1
Idle Gain—set the initial level for the Auto Level function when a gate “opens”
Output Compression—turn on/off the Output Compressor/Limiter function
Output Compression Threshold—set the point when compression begins
Output Limiter—select which inputs of Channel 1 are compressed
Gate Count Master—turn on/off the Gate Count function
Gate Count—turn on/off gate counting for each input
Ambience—turn on/off the AMB function
Ambience Threshold—set the point when the AMB function will begin to operate
Equalizer:
DSPI—force Data Signal Presence Indicator to stay on
Mute—mute the audio signal
In/Out—switches the equalizer “in” and “out” of the signal path
Store—store equalizer settings into one of ten presets per channel (A or B)
Recall—recall any stored preset
Output Gain—set the output gain
Filter—set the level of each equalizer filter
MRX-24, 24S, 12, 12S:
DSPI—force Data Signal Presence Indicator to stay on
AUX—turn on/off AUX port output
Relay—turn on/off each relay
Momentary: Use this setting if a momentary-style switch (commonly a spring-loaded push-button which
makes momentary contact when depressed and released) is connected to the drone input.
When turned on, the Momentary parameter causes the associated command to be sent when the switch is
closed and no command to be sent when it the switch is opened. This means that any “off” command (or “on”
command if the Inverted command is also turned on) will
not be sent when the switch is opened.
Inverted: Reverses the “on” and ”off” commands. The “on” commands will be sent when the switch is “off”
and the “off” commands will be sent when the switch is “on.”