11.2.4 Using a Monitor Speaker
Finally, an SLM-8 channel can be monitored from a monitor speaker. The Monitor setting in the middle of the
control block is used to select the channel to be monitored. The audio from the selected channel is then made
available at the fused monitor output on the back of the SLM-8. See the SLM-8 Reference Manual for wiring
instructions.
11.3 Configuring an SLM-8
An SLM-8 is configured from its setup sub-block. From the control block, press & or select the Setup command
and press the “Space Bar” or Left-clicking the mouose ({). The Setup Sub-block screen shown in Figure 11.5
will appear:
Fig. 11.5 The SLM-8 Setup Sub-block Screen
Each control and parameter is explained next:
Generator
The test signal generator of the SLM-8, required for impedance and frequency testing, is configured with the
following controls:
Sweep Enable: Enables or disables the generator.
Amplitude: Sets the output level of the generator. Its range is –40 dBu to +10 dBu in ½ dB steps.
Osc Enable: Immediately turns on or off the signal generator when a test is
not being performed. When
turned on with this control, the generator will output a fixed sine wave at the frequency specified by the Osc
Frequency parameter.