Software Instruction Manual

IQ–MSD Turbo 1.4 Advanced IQ System Software
Page 27
2
current settings will be uploaded and its control block and sub-blocks updated. Note: This feature does not enable
Turbo to find
new IQ components that do not yet have a control block. To add new components you must either
run a roll call or manually create a control block for each new component.
Search Loop #: Can be used to locate a break in a particular Crown Bus loop. To use this function, first enter
the Search Loop number. Then activate the Search button (shortcut: press
A+s). If there is a break in the loop,
Turbo will display its approximate location.
Search: Causes Turbo to immediately begin searching the specified Crown Bus loop for breaks in communi-
cation. The loop is specified by the preceding Search Loop # control.
Solo Function Enabled: Activates the solo feature so the Solo controls located on individual amplifier
control blocks are enabled. If this control is turned off, the amplifier Solo controls will not work. It provides a way to
have global control over the solo feature.
Emergency Mute: Activates the emergency mute feature which allows an operator to quickly mute certain
IQ components by rapidly pressing the “Space Bar” five or more times. The IQ components affected by the
emergency mute feature are all the mixers (MPX-6, SMX-6, AMB-5) and amplifiers with IQ P.I.P.s (including IQ2
P.I.P.s).
Remote Emergency Mute: Activates a feature whereby an external logic signal sensed by an AUX port
of an IQ component is used to trigger an emergency mute.
Address: Specifies the Crown Bus loop, component type and IQ address of the IQ component whose AUX port
input will be monitored for the remote emergency mute feature. Use the following procedure to determine the
address:
1 Begin with “L” followed by the loop number of the IQ component.
2 Use one of the following three-letter mnemonics for the component type:
AMP Amplifier with IQ–P.I.P.–AP (version 1.45 or later)
MPX MPX-6 mixer
SMX SMX-6 mixer
AMB AMB-5 mixer
MRX MRX-24 or MRX-12 matrixer
PSI Pocket Serial Interface
SLM SLM-8 system and load monitor
3 Specify the IQ address of the component after the component type.
Notes: Case does not matter. Commas and spaces are ignored and can be added to improve readability.
Here are a couple of examples:
L1 SMX5
L3, AMP 1
SMX Max Gain Auto Compensation: This control is only relevant when programming an analog
input of a DRN-16 drone to control the Max Gain of an SMX-6 mixer. A better way to accomplish this is to turn on
the Max Gain to Track Control Block and Control Block Override switches in the first SMX sub-block and then
assign a drone pot to an SMX-6 attenuator. (Please contact Crown’s Technical Support Group for more informa-
tion.)