Xs Series Power Amplifiers page 2 Operation Manual
Xs Series Power Amplifiers DECLARATION of CONFORMITY Crown International, Inc. Issued By: Sue Whitfield 574-294-8289 swhitfield@crownintl.com Crown International, Inc. 1718 W. Mishawaka Road Elkhart, Indiana 46517 U.S.A.
Xs Series Power Amplifiers Table of Contents page 4 Important Safety Instructions ........................................................... 2 3.2 Front Panel Controls and Indicators ..................................... 12 Declaration of Conformity ................................................................ 3 3.3 Back Panel Controls and Connectors (2-channel models).....13 1 Welcome ....................................................... 5 3.4 Back Panel Controls and Connectors (Xs4300)......
Xs Series Power Amplifiers Xs500 2-ohm Dual (per ch.) 4-ohm Dual (per ch.) 8-ohm Dual (per ch.) 4-ohm Bridge 8-ohm Bridge 1 kHz Power* 750W** 500W 400W 1,600W** 1,450W *1 kHz Power: refers to maximum average power in watts at 1kHz with 0.15% THD. ** at 0.5% THD. Xs700 2-ohm Dual (per ch.) 4-ohm Dual (per ch.) 8-ohm Dual (per ch.) 4-ohm Bridge 8-ohm Bridge 1 kHz Power* 900W** 750W 450W 1,900W** 1,645W *1 kHz Power: refers to maximum average power in watts at 1kHz with 0.15% THD. ** at 0.5% THD.
Xs Series Power Amplifiers page 6 Operation Manual
Xs Series Power Amplifiers 2 Setup 2.4 Choose Input Wire and Connectors Crown recommends using pre-built or professionally wired balanced line (two-conductor plus shield), 22-24 gauge cables and connectors. At the amplifier inputs, use either: • 3-pin male XLR cable ends, • TRS or TS 1/4" phone plugs, or • Phoenix-style connectors (2-channel models only). Unbalanced lines may be used, but may result in noise over long cable runs. Figure 2.3 shows XLR wiring, Figure 2.
Xs Series Power Amplifiers page 8 Operation Manual
Xs Series Power Amplifiers Operation Manual page 9
Xs Series Power Amplifiers 2 Setup NOTE: In Bridge-Mono mode, only the Channel 1 Level control is functional. 2.7 Connect to AC Mains Connect your amplifier to the AC mains power source (power outlet) with the supplied AC power cordset. First, connect the IEC end of the cordset to the IEC connector on the amplifier; then, plug the other end of the cordset to the AC mains. The AC Mains indication light on the front panel should be lit.
Xs Series Power Amplifiers 3 Operation 3.1 Precautions Your amplifier is protected from internal and external faults, but you should still take the following precautions for optimum performance and safety: 1. Before use, your amplifier first must be configured for proper operation, including input and output wiring hookup. Improper wiring can result in serious operating difficulties.
Xs Series Power Amplifiers page 12 Operation Manual
Xs Series Power Amplifiers Operation Manual page 13
Xs Series Power Amplifiers 3 Operation 3.4 Back Panel Controls and Connectors (Xs4300) A. Normal/Bridge Switch (one per channel pair) One per channel, XLR-1/4" combo connector includes 3-pin female XLR connector and TRS 1/4" phone jack. Accepts balanced or unbalanced signals. Two-position switch selects between normal (stereo) operation and Bridge-Mono operation. D. 5-Way Binding Post Output Connectors B. Circuit Breaker One pair per channel; accept banana plugs, spade lugs or bare wire.
Xs Series Power Amplifiers 4 Advanced Features and Options NOTE: For detailed information about these Crown amplifier features, please consult the Crown Amplifier Application Guide, available on the Crown website at www.crownaudio.com. 4.1 Protection Systems Your Crown amplifier provides extensive protection and diagnostic capabilities, including output current limiting, microprocessor-controlled DC protection, circuit breaker, and special thermal protection for the unit’s transformers. Figure 4.
Xs Series Power Amplifiers 5 Troubleshooting CONDITION: No sound. CONDITION: Normal operation. POSSIBLE REASONS: POSSIBLE REASON: • The amplifier has just turned on and is still in the 4-second turn-on delay. • The amplifier is in “fault” mode. A Fault status can be triggered when one of the amplifier’s protection circuits is activated. First disconnect your speakers from the affected channels(s) one by one to determine if one of the loads is shorted.
Xs Series Power Amplifiers 6 Specifications Minimum Guaranteed Power Xs500 Xs700 Xs900 Xs1200 Xs4300 Dual, 2 ohms (per ch.) 750W* 900W* 1200W* 1600W* Not rated Dual, 4 ohms (per ch.) 500W 750W 900W 1100W 300W Dual, 8 ohms (per ch.) 400W 450W 600W 650W 200W Bridge mono, 4 ohms 1600W* 1900W* 2500W* 3000W* Not rated Bridge mono, 8 ohms 1450W 1645W 2100W 2300W 700W Performance Xs500 Xs700 Xs900 Xs1200 Xs4300 1.4V 1.4V 1.4V 1.4V 1.
Xs Series Power Amplifiers 6 Specifications Performance Xs500 Xs700 Xs900 Xs1200 Xs4300 > 200 > 200 > 200 > 200 > 200 Crosstalk (below rated power) at 1 kHz at 20 kHz > 55 dB > 55 dB > 55 dB > 55 dB > 67 dB > 62 dB > 65 dB > 45 dB > 57 dB > 40 dB DC Output Offset (Shorted input) ± 75 mV ± 75 mV ± 75 mV ± 75 mV ± 75 mV 20 kilohms, 10 kilohms 20 kilohms, 10 kilohms 20 kilohms, 10 kilohms 20 kilohms, 10 kilohms 20 kilohms, 10 kilohms 2-8 ohms 4-8 ohms 2-8 ohms 4-8 ohms 2-8 ohms 4
Xs Series Power Amplifiers 7 AC Power Draw and Thermal Dissipation This section provides detailed information about the amount of power and current drawn from the AC mains by Xs Series amplifiers and the amount of heat produced under various conditions. The calculations presented here are intended to provide a realistic and reliable depiction of the amplifiers. The following assumptions or approximations were made: • The amplifier’s available channels are loaded, and full power is being delivered.
Xs Series Power Amplifiers 7 AC Power Draw and Thermal Dissipation Figure 7.1 Xs500 Power Draw, Current Draw and Thermal Dissipation at Various Duty Cycles Figure 7.2 Xs700 Power Draw, Current Draw and Thermal Dissipation at Various Duty Cycles Figure 7.
Xs Series Power Amplifiers 7 AC Power Draw and Thermal Dissipation Operation Manual page 21
Xs Series Power Amplifiers 8 Service Crown amplifiers are quality units that rarely require servicing. Before returning your unit for servicing, please contact Crown Technical Support to verify the need for servicing. list of authorized service centers in your area can be obtained from the Crown website at www.crownaudio.com, or by calling Crown Customer Service. This unit has very sophisticated circuitry which should only be serviced by a fully trained technician.
Xs Series Power Amplifiers 9 Warranty UNITED STATES & CANADA SUMMARY OF WARRANTY 3 AR YE Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship.
Xs Series Power Amplifiers 9 Warranty WORLDWIDE EXCEPT USA & CANADA SUMMARY OF WARRANTY 3 AR YE Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A.
Xs Series Power Amplifiers THIS PAGE INTENTIONALLY LEFT BLANK Operation Manual page 25
Xs Series Power Amplifiers THIS PAGE INTENTIONALLY LEFT BLANK page 26 Operation Manual
Xs Series Power Amplifiers Crown Factory Service Information Shipping Address: Crown Factory Service, 1718 W. Mishawaka Rd.