Owners Manual

Page 25 of 66
TROUBLESHOOTING:
If the large thermally sensitive coupling nut is exposed to
temperatures above 115°- 150°C
(240° & 300°F)
it will soften and allow the regulator
probe to Disengage from the cylinder valve, thereby shutting off the flow of gas.
Should this occur, do not attempt to reconnect the nut. Remove the entire regulator
assembly and replace it with a new one. The cause of the excessive heat should be
determined and corrected before operating the grill/side burner again.
The regulator probe also contains a flow-sensing element, which will limit the flow of
gas to the regulator to a manageable amount (10 cubic feet per hour) in the event of a
FIGURE 6. LP TANK RETENTION STRAP-MODULAR STORAGE CABINET.
NOTE: 30 LBS. TANK SHOWN CAN ONLY BE USED WITH GRILLS THAT
HAVE A BTU CAPACITY EQUAL TO OR GREATER THAN 80,000 BTU’s.