Owners Manual

Page 33 of 66
For the mobile, Non-Modular Grill models, IE30, IE36,IE42 and IE36I, the gas supply
connection is positioned inside the cabinet on the right hand back rear corner. The
grills are equipped with a with a 10 foot (3 m) hose and quick-connect fitting. The
regulation of gas from the bulk tank must be adjusted to 11.0 inches W.C., refer to the
appliances rating plates in appendix “A” (See “Figure 10” for installation details).
For fixed modular grill and side burner models, IGM24, IGM36, IGM42 and ICM-SB, the
gas connection is positioned inside the cabinet on the right hand back rear corner. The
connection is fitted with a 3/4 inch male flare fitting and the certified gas installer will
connect the gas supply at this fitting. The regulation of gas from the bulk tank must be
adjusted to 11.0 inches W.C., refer to the appliances rating plates in appendix “A” (See
“Figure 10” for installation details).
For Built-In grills and side burners, the regulator is provided separately. The appliances
are equipped with a 1/2 O.D. corrugated gas line with a 3/4 inch female flare fitting.
The connection to the regulator and gas supply must be done in accordance with this
manual and completed by a certified gas technician. The regulation of gas from the
bulk tank must be adjusted to 11.0 inches W.C., refer to the appliances rating plates in
appendix “A” (See “Figure 9” for further details).
WARNING:
The Operating Pressure of the appliance is 11.0" W.C. A step-down regulator MUST
be used on an LP house system to reduce the pressure down to 11.0" W.C. for the grill.
IMPORTANT:
Always close the gas supply shutoff valve before disconnecting the appliance’s
gas supply hose.
IMPORTANT:
An installer-supplied safety shutoff valve MUST be installed on the liquid
propane gas supply line for the appliance. The valve should be easily accessed and located
between 3 and 20 feet (1 to 6 m) away from the oven. All gas connections should be made by a
licensed technician. The installation and all installer-supplied parts must conform to local codes.
In the absence of local codes, the installation and all parts should conform to the National Fuel
Gas Code, ANSI Z223.1/ NFPA 54 or Natural Gas and Propane Installation Code, CSA B149.1.
IMPORTANT:
Diameter and length of the gas supply pipe may limit the pressure and BTU
delivery of gas to the unit. The installer must ensure proper delivery to the appliance or it will
not operate properly
(See Appendix “B” for further details).
The appliance and its individual
shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at pressures in excess of 1/2 psi (3.5 kPa). During any pressure testing of
the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa), the
appliance must be isolated from the system by closing its individual manual shutoff valve.
All pipe sealants must be of an approved type
.