Datasheet

Commands
Table 6: Supported ATA Command Set
See ATA-8 standard for command details
Command Name Command Code (hex)
CHECK POWER MODE 98h or E5h
DATA SET MANAGEMENT 06h
DEVICE CONFIGURATION RESTORE B1h/C0h
DEVICE CONFIGURATION FREEZE LOCK B1h/C1h
DEVICE CONFIGURATION IDENTIFY B1h/C2h
DEVICE CONFIGURATION SET B1h/C3h
DOWNLOAD MICROCODE 92h
EXECUTE DEVICE DIAGNOSTIC 90h
FLUSH CACHE E7h
FLUSH CACHE EXT EAh
IDENTIFY DEVICE ECh
IDLE E3h or 97h
IDLE IMMEDIATE E1h or 95h
INITIALIZE DEVICE PARAMETERS 91h
NOP 00h
READ BUFFER E4h
READ DMA (with retry) C8h
READ DMA (without retry) C9h
READ DMA EXT 25h
READ FPDMA QUEUED 60h
READ LOG EXT 2Fh
READ LOG DMA EXT 47h
READ MULTIPLE C4h
READ MULTIPLE EXT 29h
READ NATIVE MAX ADDRESS F8h
READ NATIVE MAX ADDRESS EXT 27h
READ SECTOR(S) EXT 24h
READ SECTOR(S) (with retry) 20h
READ SECTOR(S) (without retry) 21h
READ VERIFY SECTOR EXT 42h
READ VERIFY SECTOR(S) (with retry) 40h
REQUEST SENSE DATA EXT 0Bh
SANITIZE DEVICE B4h
SECURITY DISABLE PASSWORD F6h
SECURITY ERASE PREPARE F3h
SECURITY ERASE UNIT F4h
M500DC 1.8-Inch NAND Flash SSD
Commands
PDF: 09005aef854f62f9
M500DC_1_8_disti.pdf - Rev. D 4/14 EN
22
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.