TECHNICAL DATA GAS TYPE: NATURAL GAS GAS PRESSURE: 20mbar CONNECTION 8mm TUBE INJECTOR manual control: INJECTOR remote control: CAT 82/420 BRAY CAT 82/400 BRAY HEAT INPUT 6.5kW HIGH 4.1kW LOW CAT 12H DATA BADGE ON FRONT BOTTOM SECTION OF APPLIANCE IMPORTANT NOTES THIS APPLIANCE IS FITTED WITH AN ATMOSPHERE SENSING DEVICE AND CAN ONLY BE FITTED IN CONJUNCTION WITH THE FOLLOWING FLUES. CONVENTIONAL BRICK OR STONE CHIMNEY.
WARNING THIS APPLIANCE HAS A NAKED FLAME, AS WITH ALL SUCH FIRES IT IS RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE PROTECTION OF CHILDREN, THE ELDERLY AND INFIRM. FIRE GUARDS SHOULD CONFORM TO BS8423 2002 (FIREGUARDS FOR FIRES AND HEATING APPLIANCES FOR DOMESTIC USE-SPECIFICATION) INSTALLATION REQUIREMENTS PRE CAST FLUES A PRECAST FLUE CONFORMING TO THE REQUIREMENTS OF BS 1289 PART 1.
CONVENTIONAL CHIMNEY A CONVENTIONAL BRICK OR STONE CHIMNEY AS USED FOR SOLID FUEL APPLIANCE WITH A MINIMUM EFFECTIVE CROSS SECTIONAL DIMENSION OF 225*225mm, WITH A MINIMUM OF 3 METERS EFFECTIVE HEIGHT. A LINED FLUE WITH A MINIMUM DIAMETER OF 125mm WITH THE FIREPLACE COMPONENTS CONFORMING TO BS 1251 A BUILDERS OPENING A MINIMUM OF 560mm HIGH AND 400mm WIDE WITH A MINIMUM DEPTH OF 230mm TO ALLOW SUFFICIENT VOLUME OF DEBRIS COLLECTION.
THE RELEVANT BRITISH STANDARDS MUST BE FOLLOWED BS 5871 :PART 3 BS 5440: PART 1 AND 2 BS 6891 BS 8303 BS 1251 AND I.S 813 FOR IRELAND A BRICK CHAMBER TO THE SIZES IN FIG 2 IN AN EXISTING BRICK OR STONE CHIMNEY A 125mm MINIMUM DIAMETER FLUE LINER CONFORMING TO BS715 MAY BE USED, PROVIDING IT IS SEALED AT THE TOP AND BOTTOM OF THE EXISTING BRICK OR STONE CHIMNEY.
INSTALLATION REQUIREMENTS 5”(125mm) FLUE PIPE AND STARTER BOX A DOUBLE WALLED SELKIRK RECESSED FLUE BOX BUILT TO THE REQUIRMENTS OF BS 715 WITH AN INSULATED FLUE HAVING A MINIMUM DIAMETER OF 125mm(5”) AND A MINIMUM EFFECTIVE OVERALL HEIGHT OF 3 METRES (10FT) 143mm c 560mm 610mm 330mm 457mm 330mm 407mm RECESSED GAS FLUE BOX DIMENSIONS(NOT INCLUDING FIBREGLASS INSULATION) NOTE THE METAL FLUE BOX MUST BE INSULATED WITH FIBREGLASS OR EQUIVALENT TO A THICKNESS OF 25mm NOTE WHERE INSTALLATION IS FOR A METAL
A NON COMBUSTIBLE HEARTH MUST BE PROVIDED BENEATH THE APPLIANCE WITHIN THE FIREPLACE OPENING. A FIRE RESISTANT HEARTH MUST ALSO BE PROVIDED SYMMETRICALLY DISPOSED ABOUT THE FIREPLACE OPENING A MINIMUM THICKNESS OF 12mm WITH THE PERIMETER 50mm ABOVE THE FLOOR LEVEL THE WIDTH MUST EXTEND A MINIMUM OF 150mm EITHER SIDE OF THE FIREPLACE OPENING AND A DEPTH OF 300mm FROM THE FUEL BED ANY COMBUSTIBLE MATERIAL MUST BE REMOVED ABOVE THE OPENING TO A HEIGHT OF 900 mm ABOVE THE HEARTH LEVEL.
CHECKING GAS PRESSURE AND SOUNDNESS REMOVE THE PRESSURE TEST POINT SCREW FROM THE INLET ELBOW AND CONNECT PRESSURE GAUGE. TURN ON GAS TO APPLIANCE. ROTATE THE CONTROL TO THE IGNITION POSITION AND PUSH IN TO ALLOW THE AIR IN THE PIPEWORK TO BE PURGED. PUSH IN PIEZO IGNITION SWITCH CHECK THAT THE ELECTRODE IS SPARKING. CONTINUE SPARKING UNTIL PILOT IGNITION IS ESTABLISHED. TURN THE GAS CONTROL KNOB ON TO THE HIGH POSITION AND ALLOW TO RUN FOR FIVE MINUTES. CHECK THE INLET PRESSURE IS 20 MBAR.
RUBY RANDOM PEBBLE LAYOUT SIX RANDOM PEBBLES FIT FLUSH ON TOP OF FRONT FIBRE, PUSHED AS FAR TOWARDS THE BACK FIBRE BUT NOT OVER THE BURNER.
TEST FOR SPILLAGE CHECK FOR SATISFACTORY CLEARANCE OF COMBUSTION PRODUCTS CLOSE ALL DOORS AND WINDOWS IN THE ROOMS CONTAINING THE FIRE.
SERVICING NOTES GENERAL NOTES.
LOCKNUT "B" INJECTOR RE ASSEMBLE IN REVERSE ORDER TURN ON GAS SUPPLY. CHECK FOR SOUNDNESS AND RECOMMISION THE FIRE.
BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY RUBY DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I2H FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E.
USERS INSTRUCTIONS FOR RUBY GAS APPLIANCE YOUR RUBY GAS APPLIANCE IS A DECORATIVE LIVE FUEL EFFECT GAS FIRE ,DUE TO ITS NEWNESS THE FIRE MAY GIVE OFF SLIGHT SMELL FOR A SHORT PERIOD AFTER INSTALLATION .THIS IS QUITE NORMAL AND WILL DISAPPEAR AFTER A FEW HOURS OF OPERATION. THE APPLIANCE TO WHICH THESE INSTRUCTIONS APPLY MUST BE INSTALLED BY A COMPETENT PERSON(EG. A C.O.R.G.
WITH A TAPER IS AN EMERGENCY MEASURE ONLY AND THE APPLIANCE SHOULD BE SERVICED AS SOON AS POSSIBLE”.AND THEN PROCEED AS STATED IN PARAGRAPHS 2/7. IMPORTANT .THIS APPLIANCE IS FITTED WITH AN OXYGEN DEPLETION SENSOR INCORPORATED INTO THE PILOT BODY.SHOULD THE FIRE REEATEDLY EXTINGUISH ITSELF THEN SPECIALIST ADVISE SHOULD BE SOUGHT,AS THIS MAY INDICATE SPILLAGE INTO THE ROOM OF COMBUSTION PRODUCTS. GB/ IE CAT12h G20AT20mbar hot HEAT INPUT HIGH 6.5Kw LOW 4.
RUBY GAS FIRE LIGHTING WITH TAPER TO LIGHT WITH TAPER ,PUSH LIGHTED TAPER AS SHOWN WHILST FOLLOWING THE OPERATING INSTRUCTIONS "D" "D" "D" "D" "B" "D" "B" "D" "D" "D" "D" "D" "D" TAPER FUEL BED LAYOUT PERIODICALLY SMALL DEPOSITS OF SOOT MAY GATHER ON THE FUEL BED AND BURNER, THIS MUST BE REMOVED BY REMOVING FUEL AND BRUSHING ANY DEPOSITS WITH A SOFT BRUSH AND VACUUMING THE BURNER, THEN REPLACE FUEL USING THE FOLLOWING PROCEDURE.
RUBY RANDOM PEBBLE LAYOUT SIX RANDOM PEBBLES FIT FLUSH ON TOP OF FRONT FIBRE, PUSHED AS FAR TOWARDS THE BACK FIBRE BUT NOT OVER THE BURNER.