Technical data

"B"
INJECTOR
LOCKNUT
RE ASSEMBLE IN REVERSE ORDER
TURN ON GAS SUPPLY. CHECK FOR SOUNDNESS AND RECOMMISION
THE FIRE.
REPLACEMENT OXY PILOT ASSEMBLY
DISCONNECT FIRE AT INLET ELBOW
REMOVE FIRETRAY
DISCONNECT THERMOCOUPLE AT GAS VALVE
DISCONNECT GAS CONNECTION FROM PILOT ASSEMBLY
REMOVE IGNITOR LEAD FROM PILOT ASSEMBLY
UNDO SCREWS SECURING OXY PILOT TO FIRETRAY
RE-ASSEMBLE IN REVERSE ORDER
TURN ON GAS SUPPLY,CHECK FOR SOUNDNESS AND RE-COMMISION
APPLIANCE
CLEANING
BEFORE CLEANING ANY PART OF THE FIRE ,ENSURE THAT THE GAS IS
TURNED OFF AND FIRE IS COOL.
BLACK PAINT
USE ONLY CLEAN DAMP CLOTH ,DO NOT USE ANY CLEANING AGENTS
BRASS TRIM/CHROME
USE BRASSO,OR CHROME CLEANER ENSURING YOU REMOVE THE
BRASS TRIM FROM THE APPLIANCE BEFORE CLEANING
IMPORTANT
THE PAINT AND BRASS FINISH ARE DURABLE BUT WILL BE DAMAGED
IF PLASTER,CEMENT,OR WALLPAPER PASTE COMES IN CONTACT WITH
IT
COALS AND CERAMICS
IF FOR ANY REASON IT IS NECCESARY TO REMOVE CERAMIC
PARTS,THEN BEFORE REPLACEMENT THE BURNER SHOULD BE
CHECKED THAT NO PARTICLES HAVE DEPOSITED ON THE BURNER
AND IF NECCESARY VACUUM THEM CAREFULLY,THEN REFER TO
INSTRUCTIONS FOR REPLACING CERAMICS.
CERAMICS SHOULD BE CLEANED BY SHAKING ANY DEBRIS
NO BRUSHING OR VACUUMING SHOULD BE PERFORMED .
INSTALLER SPARE PARTS
FUEL BED RUBY001 MAIN MATRIX RUBY002
FRONT FIBRE RUBY 003 INSTUCTIONS RUBY 004
TRIM RUBY 005 ODS COMPLETE RUBY 006
GAS VALVE RUB007
INJECTOR REMOTE CONTROL RUBY007 CAT 82/400
ISSUE 2
13
INJECTOR MANUAL CONTROL RUBY008 CAT 82/420