Technical data

WARNING
THIS APPLIANCE HAS A NAKED FLAME, AS WITH ALL SUCH FIRES IT
IS RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE
PROTECTION OF CHILDREN, THE ELDERLY AND INFIRM. FIRE
GUARDS SHOULD CONFORM TO BS8423 2002 (FIREGUARDS FOR FIRES
AND HEATING APPLIANCES FOR DOMESTIC USE-SPECIFICATION)
INSTALLATION REQUIREMENTS
PRE CAST FLUES
A PRECAST FLUE CONFORMING TO THE REQUIREMENTS OF BS 1289
PART 1.FOR DETAILS OF THE DIMENSIONS REQUIRED TO LOCATE
POSITION OF THE APPLIANCE WITHIN THE OPENING/STARTER BLOCKS
SEE FIG 1.
WITH A MINIMUM 3 METERS EFFECTIVE HEIGHT.
400mm
560mm
200mm
300mm
765mm
50mm
FIG 1
NOTE
AN INSPECTION SHOULD BE MADE TO ENSURE THAT THE INTERNAL
WALLS OF THE FLUE ARE CLEAR OF MORTAR FANGS PRIOR TO
INSTALLING THE APPLIANCE.
A 50mm SPACER CAN BE FITTED TO ALLOW MORE DEPTH IF REQUIRED
USING THE FOLLOWING PROCEDURE.
MARK POSITION OF FLANGE HOLES, DRILL AND PLUG AND FIX SPACER
USING FOAM SEAL SUPPLIED. THEN SCREW FIRE TO SPACER SEALING
WITH FOAM SEAL SUPPLIED AND SCREWS SUPPLIED WITH SPACER.
ISSUE 2
4