Specifications

12-VOLT SYSTEM
Total length of Cable in Circuit from Battery to Most Distant Lam p
AMPS
(Appl).
Candle
Power
2.5
Ft.
GA.
5
Ft.
GA.
10
Ft.
GA.
20
Ft.
GA.
30
Ft.
GA.
40
Ft.
GA.
50
Ft.
GA.
60
Ft..
GA.
80
Ft.
Ga.
100
Ft.
Ga.
1.0 6 20 20 20 20 20 20 20 20 20 18
1.5 1020202020202020201818
2 1620202020202018181616
3 2420202020201818161614
4 3020202020181616161412
5 4020202018181614141212
6 5020202018161614141212
7 6020202018161414121210
8 7020202016161412121010
10 80 20 20 18 16 14 12 12 12 10 10
11 90 20 20 18 16 14 12 12 10 10 8
12-VOLT SYSTEM
Total length of Cable in Circuit from Battery to Most Distant Lamp
AMPS
(Appl).
Candle
Power
2.5
Ft.
GA.
5
Ft.
GA.
10
Ft.
GA.
20
Ft.
GA.
30
Ft.
GA.
40
Ft.
GA.
50
Ft.
GA.
60
Ft..
GA.
80
Ft.
Ga.
100
Ft.
Ga.
12 100 20 20 18 16 14 12 12 10 10 8
15 120 20 20 18 14 12 12 10 10 8 8
18 140 20 20 16 14 12 10 10 8 8 8
20 160 20 18 16 12 12 10 10 8 8 6
22 180 20 18 16 12 10 10 8 8 8 6
24 200 20 18 16 12 10 10 8 8 6 6
36 20 16 14 10 8 8 8 6 6 4
50 18 16 12 10 8 6 6 4 4 2
100 14 12 10 6 4 4 2 2 1 0
150 141084221000000
200 1286421000000
0000
WIRE GUAGE SELECTION CHART
Note: This chart is based upon a 10% voltage drop. For 5% voltage drop, use double the measured wire length. When mechanical strength is a factor, use
next larger wire gauge.
65