User guide

nano-porous systems Ltd
17-100-0100 11
4.4 Monitoring dryer performance (Energy saving option)
The dew-point is displayed on the control panel. When the dew-point displayed is
better than -48°C PDP the dryer will switch into ec onomy mode and stop cycling.
When the dew-point degrades to -42°C the dryer will restart cycling ensuring the
dew-point is maintained at or better than -40°C.
If the dryer fails to achieve dew-point (falls below -30°C), the alarm output will be
indicated on the front screen. This will permit the end user to provide for example
a 4-20mA signal through this switch to a remote monitoring station elsewhere.
4.5 Shutdown procedure
Switch off the power supply to the dryer.
Close the inlet and outlet valves.
The dryer might still be pressurised! In order to de-pressurise the dryer; ensure
the dryer is isolated from the compressed air source:
o Cycle the dryer twice to ensure the dryer exhausts and is completely
depressurised.
o When fully depressurised the ‘clicking’ of the exhaust valves will be
heard but no air exhausted.
When the dryer is fully depressurised, isolate from the power supply.
Figure 6: Control Panel