Product Manual

EN
EN • 5
1
VOLTAGE (V)CURRENT (A)
PULSE
DESULPHATION BULK ABSORPTION
Increasing voltage
to 7.2V
0.8A
1
7.2V 7.2V
Declining current
6.4V‒7.2V
0.8‒0.4A
2 3 4
CHARGING PROGRAM
XC 0.8 is equipped with a multi purpose charging program. XC 0.8 charges all batteries 1.2100Ah
in the temperature range of -20˚ to +50˚C (-4˚F to +122˚F).
CTEK SWEDEN AB, issues this limited warranty to
the original purchaser of this product. This limited
warranty is not transferable. The warranty applies
to manufacturing faults and material defects for
5 years from the date of purchase. The customer
must return the product together with the receipt of
purchase to the point of purchase. This warranty
is void if the battery charger has been opened,
handled carelessly or repaired by anyone other
than CTEK SWEDEN AB or its authorised repre-
sentatives. CTEK SWEDEN AB makes no war-
ranty other than this limited warranty and is not
liable for any costs other than those mentioned
above, i.e. no consequential damages. Moreover,
CTEK SWEDEN AB is not obligated to any war-
ranty other than this warranty.
LIMITED WARRANTY
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing cur-
rent and voltage, removes sulphate from
the lead plates of the battery restoring
the battery capacity.
STEP 2 BULK
Charging with maximum current until
approximately 80% battery capacity.
STEP 3 ABSORPTION
Charging with declining current to maxi-
mize up to 100% battery capacity.
STEP 4 PULSE
Maintaining the battery at 95–100%
capacity. The charger monitors the
battery voltage and gives a pulse when
necessary to keep the battery fully
charged.