Owner manual

CTI Products, Inc. NCB-AY User Guide
Appendix C. Connector Details 38
3 Pin Terminal Strip style:
Mating Connector: Weidmuller 128186
Pin
Function
1
Network
2
Network
3
Shield (RS-485 only)
SMX Transceiver units:
SMX network connections are described in the documentation with the SMX
transceiver.
PORT 1 and PORT 2 Connectors
Connector type: Standard DE9 male
Data Format: 8 data bits, 1 stop bit, no parity
Data Characteristics: A series of bytes entering the “PORT 1” or “PORT 2”
connectors must not have gaps between bytes greater than 500ms.
Handshaking: Activating the DSR input signal informs the NCB unit that the channel is
active. If the channel does not directly support DSR, it must be strapped
back to the (always active) DTR output signal.
Flow Control: CTS/RTS flow control can be used to pace the transmission of individual
bytes between the NCB and a connected device. Sensing of CTS by the
NCB can be enabled/disabled with the Option B switches. (See “STEP 2.
SWITCH SETUP”, in section “2. SETUP AND OPERATION”.)
Pin
Function
Direction
1
DCD
Channel NCB
2
RXD
Channel NCB
3
TXD
NCB Channel
4
DTR
NCB Channel
5
ground
6
DSR
Channel NCB
7
RTS
NCB Channel
8
CTS
Channel NCB
9
RI
Channel NCB
NETWORK
1 2 3
C A - 8 0 0 8 5 - 1 0 0
PORT 1
1
2
3
4
6
7
8
9
5
NETWORK
2
1