Service manual

CCuulllliiggaann
®
MMaarrkk 110000 GGeenneerraattiioonn 11 CCiirrccuuiitt BBooaarrdd
Used from 7/94 to 6/98
Replacement PN: 01-0042-94 - 110 volt
01-0063-24 - 24 volt
Status: Obsolete, replace with 01-0146-64
Control Functions
Programming Switches
FUNCTION
1. Time of Day
2. Time of Regeneration
3. Salt Dosage
4. Backwash Time
5. Brine Ruse
6. Hardness
7. Regeneration Interval
TIME CLOCK
Yes
Yes
Yes
Yes
Yes
No
Yes
SOFT MINDER METER
Yes
Yes
Yes
Yes
Yes
Yes
No
AQUA-SENSOR
Yes
Yes
Yes
Yes
Yes
No
No
DEFAULT
12:00 AM
2:00 AM
10lb for 9”; 16lb for 12”
10 min.
71 min. for 9”; 59 min. for 12”
20 GPG
3 days
DIP SWITCH
1
2
3
4
5
6
7
FUNCTION
Soft-Minder Meter
Aqua-Sensor
9" or 12 " Tank
50 or 60 HZ
Standard or Accelerated Refill
Delay or Immediate Regeneration
N/A
DEFAULT (OFF POSITION)
Timeclock
Timeclock
9” Tank
60HZ
Standard Refill
Delayed Regeneration
N/A
CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
9