Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
11
7. Press status. Set Regeneration Interval (1-42 days).
TIME CLOCK MODELS ONLY.
3
123 456 7
5. Press status. Set Brine Rinse Time (37-85 minutes for
9”, 35-89 minutes for 12”). TIME CLOCK
AND METER MODELS ONLY.
7I
5
6. Press status. Set Hardness Level (1-75 gpg for 9”,
1-99 gpg for 12”).
METER MODELS ONLY.
20
123 456
Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
PPrrooggrraammmmiinngg
Service Check Mode
The service check mode allows one to view the instantaneous flow rate (0.5-1.0 gpm, meter models only), The
days since the last regeneration,and the number of regenerations in the past fourteen days. To enter the service
check mode, follow these steps:
1. Press the STATUS key until the display is
blank.
2. Press the DOWN arrow. (Soft-Minder®
meter models only)
3. Press the down arrow.
4. Press the down arrow.
5. Press the STATUS key twice.
Display in blank.
Displays instantaneous flow. The
FLOW segment will be lit. An -:-
display indicates flow greater than
10.0 gpm.
Displays number of days since last
regeneration. LAST segment is lit
Displays the number of regenera-
tions within the past fourteen days.
The #REGEN segment will be lit. If
0, then no regenerations occurred
within the past fourteen days.
The display will show Time-of-Day.
FLOW 5:5
LAST
2
#REGEN 8
8:00
AM