Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
18
The service check mode allows one to view the instantaneous flow rate, the days since the last regeneration,
the total number of regenerations, the regenerations in the past fourteen days, and the gallons remaining.
To enter the service check mode, follow these steps:
SSeerrvviiccee CChheecckk
1. Press the status key to move past steps 1-10 until the
display is blank.
2. Push the down arrow. The number '12' will appear only
when the Soft-Minder
®
meter is connected. The display
reads the gallons per minute flow rate. This screen will
update with the current meter reading every 6 seconds.
3. Press the down arrow. The number '13' will light at the
bottom of the display. The display will indicate the num-
ber of regenerations that have occurred in the last 14
days.
4. Press the down arrow. The number '14' will light at the
bottom of the display. The number in the display indi-
cates the number of days since last regeneration.
5. Press the down arrow. The number '15' will be dis-
played if the flow meter or Aqua-Sensor
®
is connected.
For the controls with the Soft-Minder
®
meter, the display
indicates the gallons remaining before the unit signals
for regeneration (multiply the displayed number by 10).
For Aqua-Sensor
®
controls, the number indicates the
total minutes of the last brine rinse cycle.
NOTICE: Pushing the up arrow at any of these displays will immediately bring you to the control position
display, the number '11' will light at the bottom of the display.