Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
19
MMaannuuaall CCyycclliinngg
The Culligan
®
microprocessor can be indexed through the various regeneration stages. For all steps, the
cycle numbers do not appear, or change, until the motor stops.
1. Press the status button to move past steps 1-10 until the
display is blank. Push the up arrow. The number “11”
icon will light up. An "H" will appear in the display. The
control is in the HOME position. Pressing the regen but-
ton once will light the 'REGEN' icon.
2. Press the regen button one more time. The 'REGEN'
icon will blink, and the motor will advance the control. A
'1' will appear. The unit is now in the BACKWASH posi-
tion. The numbers to the right indicate the time remain-
ing for the cycle.
3. Press the up arrow. A '2' will appear in the display, along
with the cycle time remaining. The control is in the
BRINE DRAW/SLOW RINSE cycle.
4. Press the up arrow. A '3' will appear in the display, along
with the cycle time remaining. The control is in the FAST
RINSE/BRINE REFILL cycle (FAST RINSE cycle for
Platinum).
5. Press the up arrow. A “4” will appear in the display along
with the cycle time remaining for Platinum control is only.
The control is in the BRINE REFILL cycle (Culligan
Platinum Series
Controls Only).
6. Press the up arrow. An 'H' will appear in the display. The
unit is in the HOME position. The 'REGEN' enunciator is
no longer blinking. An 'H 20' will appear on the Aqua-
Sensor® models.
NOTICE: On Aqua-Sensor
®
controls the display will initially
display "H 20" and proceed to count down to zero. This is
the 20 minute signal delay built into the Accusoft
®
micropro-
cessor. The control will not allow another regeneration to
occur during this 20 minute period.
6. Press the status key. Time-of-Day appears in the display.
7:28
PM
4 07
REGEN
11