Service manual

CCuulllliiggaann SSiillvveerr SSeerriieess
,, CCuulllliiggaann GGoolldd SSeerriieess
,,
CCuulllliiggaann
®
MMaarrkk 110000 GGeenneerraattiioonn IIIIII,, && CCuulllliiggaann PPllaattiinnuumm SSeerriieess CCiirrccuuiitt BBooaarrdd
Used from 6/00 to Current
Products: Culligan
®
Mark 100 Generation III, Culligan Silver Series
, Culligan Gold Series
, and Culligan Platinum
Series
Controls
Replacement PN: 01-0130-94 -- Culligan
®
Mark 100 Generation III, Culligan Silver Series
, Culligan Gold Series
01-0141-74 -- Culligan Platinum Series
Controls
Control Functions
Programming Switches
CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
21
FUNCTION
1. Time of Day
2. Time of Regeneration
3. Not Used
3b. Fast Rinse Time
Platinum Units Only
4. Salt Dosage
5. Backwash Time
6. Brine Rinse Time
7. Hardness Level
8. Gallon Capacity /
Regen. Interval
8A.Forced Regeneration
Interval
9. Lock/Unlock Display
10. Blanking Feature
TIME CLOCK
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
SOFT-MINDER METER
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
AQUA-SENSOR
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
DEFAULT
12:00 am
2:00 am
10 min.
10 min.
10lb for 9”; 16lb for 12”
10 min.
71 min. for 9”; 59 min. for 12”
20 GPG
3 days
---
Enabled
Disabled
DIP SWITCH
1
2
3
4
5
6
7
8
9
10
FUNCTION
Run or Test Mode
Filter or Softener
Flow Meter K Factor (3/4” or 1 1/4”)
9” or 12” Tank
Standard or Accelerated Refill
Delay or Immediate Regeneration
English or Metric
12 or 24 Hour Clock
German or French Hardness Degrees
Time Clock Back-up
DEFAULT (OFF POSITION)
Run Mode
Softener
3/4” Meter
9” Tank
Standard Refill
Delayed Regeneration
English
12 Hour Clock
German (when #7 is on)
No Forced Regeneration