Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
22
CCoonnnneeccttiioonnss
Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
FIG. 3 - Circuit Board Display
The display will initially power up flashing "12:00 PM". After 1 minute the motor will energize and cycle the control,
without stopping, to the home position. This is required to ensure that the control is in the home position.
P
rogramming
The timer uses four buttons:
1. STATUS: Advance timer through display options.
2. UP ARROW: Increase the setting.
3. DOWN ARROW: Decrease the setting.
4. REGEN.: Initiate a manual regeneration.
SETTING THE MICROPROCESSOR
The microprocessor senses when it is installed as a Soft-Minder
®
or Aqua-Sensor
®
control. Adding or remov-
ing any connection to the board, or flipping any of the dip switches will automatically reset the microproces-
sor to the factory settings.
1. With a flashing or blank display, pressing the status button twice will
move to the Time-of-Day adjustment, adjust the time by using the up
and down arrows. A number “1” will appear at the bottom of the dis-
play while in this mode.
2. Press status again, this displays the Time-of-Regeneration for
delayed units, adjust using the up and down arrows. A number “2”
will appear at the bottom of the display while in this mode.
3. Press status again, the number “3” will appear at the bottom of the
display. This setting is not used, and any changes made will not
affect the operation of the microprocessor.
4. Pressing status again will show the Fast Rinse Time (for Culligan
Platinum Series
Units Only). A “3” will remain in the display and a
“B” will appear on the right side of the display. This setting can be
adjusted from 5-30 minutes.
Press to increase or
to decrease
AB