Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
24
MMaannuuaall CCyycclliinngg
The Culligan
®
microprocessor can be indexed through the various regeneration stages. For all steps, the cycle
numbers do not appear, or change, until the motor stops.
1. Press the status button to move past steps 1-10 until the display is
blank. Push the up arrow. The number “11” icon will light up. An "H"
will appear in the display. The control is in the HOME position.
Pressing the regen button once will light the 'REGEN' icon.
2. Press the regen button one more time. The 'REGEN' icon will blink,
and the motor will advance the control. A '1' will appear. The unit is
now in the BACKWASH position. The numbers to the right indicate the
time remaining for the cycle.
3. Press the up arrow. A '2' will appear in the display, along with the cycle
time remaining. The control is in the BRINE DRAW/SLOW RINSE
cycle.
4. Press the up arrow. A '3' will appear in the display, along with the cycle
time remaining. The control is in the FAST RINSE/BRINE REFILL
cycle.
5. Press the up arrow. A “4” will appear in the display along with the cycle
time remaining for Platinum control only. The control is in the BRINE
REFILL cycle (Platinum Controls Only).
6. Press the up arrow. An 'H' will appear in the display. The unit is in the
HOME position. The 'REGEN' enunciator is no longer blinking. An 'H
20' will appear on the Aqua-Sensor
®
models.
NOTICE: On Aqua-Sensor
®
controls the display will initially display "H 20"
and proceed to count down to zero. This is the 20 minute signal delay
built into the Accusoft
®
microprocessor. The control will not allow another
regeneration to occur during this 20 minute period.
7. Press the status key. Time-of-Day appears in the display.
7:28
PM
4