Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
37
Power Valve
CAUTION: Refer to the wiring schematic diagram for correct plug in reference of wire harness
connectors. Do not touch any surface of the circuit board. Electrical static discharges can damage
the circuit board. Handle the circuit board by its edges.
Insert the circuit board into the supporting bracket. The front of the circuit board must face toward the inside
of the control with the RESET/REGEN terminal located in the upper left-hand corner (refer to Figure 1).
Push the meter harness onto the circuit board at the position labeled METER.
Connect the brown wires from the reset/regeneration harness provided into the regeneration button.
Connect the purple wires into the common and NC terminals of the reset switch.
Push the reset/regeneration harness into the circuit board at the position labeled RESET/REGEN.
Push the white lead from the circuit board wire harness into the white wire from the terminal strip.
Push the black lead from the circuit board harness into the black wire from the terminal strip. Push the
orange lead from the circuit board harness into the black wire from the common terminal of the timer
program switch. Connect the green lead from the circuit board harness to the grounding screw.
Push the circuit board wire harness into the circuit board.
Delrin Valve
CAUTION: Refer to the wiring schematic diagram for correct plug in reference of wire harness
connectors. Do not touch any surface of the circuit board. Electrical static discharges can damage
the circuit board. Handle the circuit board by its edges.
Insert the circuit board into the control housing. The front of the circuit board must face toward the
outside of the control with the RESET/REGEN terminal located in the upper corner.
Push the meter harness onto the circuit board at the position labeled METER.
Connect the brown wires from the reset/regeneration harness into the regeneration button. Connect the
purple wires into the common and NO terminals of the reset switch.
Push the reset/regeneration harness into the circuit board at the position labeled RESET/REGEN.
Push the white lead from the circuit board wire harness into the backwash connector. Connect the
black lead from the circuit board harness into the terminal strip. Connect the orange lead from the
circuit board harness into the black wire from the common terminal of the timer backwash switch.
Connect the green lead from the circuit board harness to the grounding screw.
Push the circuit board wire harness into the circuit board.
Gallons Setting
Determine the daily use for the household. Usually 75-100 gallons per day per person is adequate. Using table
2A-2E (depending on the model), locate the hardness range for your water supply. Move down the column and
locate the gallons setting and salt dosage which best suits the application. Usually two to three days between re-
generation yields the best results. Allow for one half to one day water usage as reserve capacity. Set the salt
dosage per the instructions of the softener installation and operation instructions.
Set the gallons setting on the circuit board. A set of six dip switches on the circuit board determine the
gallons capacity. Refer to the table and figures when setting the dip switches.
WWiirriinngg CCoonnnneeccttiioonnss
Parts List
PART NO. DESCRIPTION QTY.
01-0101-27 Meter Circuit Board 1
01-0079-02 Harness, Wire - Meter Board 1
01-0079-01 Harness, Wire - Regen 1
00-3184-78 Screw #6-20 x 0.375 2
01-0082-55 Support Bracket 2