Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
40
CCuulllliiggaann
®
CCoommmmeerrcciiaall GGeenneerraattiioonn II CCiirrccuuiitt BBooaarrdd
Used from 6/98 to 5/26/00
Status: Obsolete, replacement with PN: 01-0128-38
Control Functions
FUNCTION MODEL TYPE DEFAULT RANGE
1. Time of Day All 12:00 AM 12 hrs. AM/PM
2. Time of Regeneration Timeclock & Delayed 2:00 AM 12 hrs. AM/PM
3. Not Used NO NA NA
4. Pulse/Gallon Meter 10.0 1.0 - 150
5. Backwash Time All 10 min. 1 -40 min.
6. Brine Rinse Time YES 60 min. 35 - 99 min.
7. Fast Rinse/Refill Time NO 10 min 1 - 30 min.
8. Gallon Capacity / Timeclock 3 days - TC 1 - 42 days
Regen. Interval Meter 1000 for "0" 0 - 99,999
10000 for "00" 0 - 99,900
9. Total Gallons Since Last Meter 0000 0 - 99,999
Circuit Board Reset 0 - 99,999,000
10. Lock/Unlock All Unlocked --
Display All Enabled --
Blanking Feature
Programming Switches
DIP SWITCH FUNCTION DEFAULT (OFF POSITION)
1 Run or Test Mode Run Mode
2 Filter or Softener Softener
3 Times 10 or Times100 Times 10
4 Alternating or Parallel Parallel
5 Not Used
6 Delay or Immediate Regeneration Delayed Regeneration
7 Not Used
8 12 or 24 Hour Clock 12 Hour Clock
9 Not Used
10 Forced Regeneration - Every Third Day No Forced Regeneration
The alternate and parallel switch is only active when dip switch 6 is set to immediate.