Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
45
9. Press status again, if the unit is a time-clock model the display will show the number of days desired between
regenerations. The setting can be adjusted using the up and down arrows. If the unit is a metered unit this will
display the number of gallons desired between regenerations. Step 8 will be skipped for Aqua-Sensor mode
unless dip switch 10 is set to ON for time clock backup. A number "8" will appear at the bottom of the display
while in this mode.
NOTICE: In the meter mode, the position of DIP switch #3 determines the multiplier of the number displayed. If the
DIP switch is in the "on" position the multiplier is 100. If the DIP switch is in the "off" position the multiplier is 10.
For example, if the display is 2700 and the DIP switch is set off the number of gallons between regenerations
is:
2700 x 10 = 27,000 gallons
If the DIP switch was in the on position:
2700 x 100 = 270,000 gallons
10. Press status again, this displays the total gallons used since the timer was last reset. This is not a user
adjustable screen, and is only displayed on metered units. See the previous instruction for an explanation of
the multiplier. A number "9" will appear at the bottom of the display while in this mode.
NOTICE: The position of DIP switch #3 determines the multiplier of the number displayed. If the DIP switch is
in the "on " position the multiplier is 10,000. If the DIP switch is in the "off" position the multiplier is 1,000.
For example, if the display is 2700 and the DIP switch is set off the number of gallons between regeneration
is:
2700 x 1000 = 2,700,000 gallons/liters
If the DIP switch was in the on position:
2700 x 10,000 = 27,000,000 gallons/liters
11. Pressing status again brings up the screen that will lock or un-lock the settings and control screen blanking.
Locked and un-locked
This setting is toggled between locked and un-locked by simultaneously pressing the up and down arrows. When
the control is locked a small padlock icon is displayed on the right hand side of the display. Locking the control pre-
vents the accidental or intentional changes of the softeners settings. When the control is locked, only the time of
day can be changed. A number "10" will appear at the bottom of the display while in this mode.
Display blanking
As shipped from the factory, the display of the board will turn off if there has been no keyboard activity for more
than a 1 minute period. To have the display constantly lit press the up arrow, a “dU” for disable will appear in the
display. Pressing the up arrow again results in an “EU” displayed showing that display blanking is enabled.
Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
99
PPrrooggrraammmmiinngg