Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
46
The service check mode allows one to view the instantaneous flow rate, the days since the last regeneration, the
number of regenerations in the past fourteen days and the gallons remaining. To enter the service check mode,
follow these steps:
1. Press the STATUS key until the display is blank. Press
the UP arrow to access step 11.
2. Push the DOWN arrow. The number 12 will appear if
the flow meter is connected. The display reads the gal-
lons per minute flow rate.
SSeerrvviiccee CChheecckk
3. Press the DOWN arrow. The number 13 lights up. The
number in the display indicates the number of regens in
the last 14 days.
5. Press the DOWN arrow. The number 15 will be dis-
played if the flow meter or Aqua-Sensor
®
is connected.
For the flow meter, display indicates the gallons re-
maining before the unit signals for a regeneration (mul-
tiply the displayed number by 10 or 100 depending on
dip switch 3 setting). For the Aqua-Sensor
®
, the display
indicates the last slow rinse time.
4. Press the DOWN arrow. The number 14 will light up.
The display will indicate the number of days since last
regeneration.