Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
47
The Culligan
®
Electronic control can be indexed through the various regeneration stages. For all steps, the cycle
numbers do not appear until the motor stops.
2.Press the REGEN button twice. The REGEN icon will
light and blink. A “1” will appear. The unit is now in the
BACKWASH position. The numbers to the right indicate
the time remaining for the cycle.
3.Press the UP arrow. A “2” will appear in the display. The
control is in the BRINE DRAW/SLOW RINSE cycle.
4.Press the UP arrow. A “3” will appear in the display. The
control is now in the FAST RINSE/BRINE REFILL cycle.
5.Press the UP arrow. An “H” will appear in the display.
The unit is in the HOME position. The REGEN enunciator
is no longer blinking. Note: A 30 minute delay will show if
an Aqua-Sensor® is connected to the circuit board.
MMaannuuaall CCyycclliinngg
1.Press the STATUS button until the display is blank. Push
the UP arrow. An “H” will appear in the display. The num-
ber 11 icon will light up. The control is in the HOME posi-
tion.
6.Press the STATUS key. Time-of-Day appears in the dis-
play.