Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
53
1. Turn on the power to the control.
2. Display will be flashing.
3. Press status twice; 12:00 PM will appear, this is the time of day, adjust using the up and down arrows. A number
"1" will appear at the bottom of the display while in this mode.
4. Press status again, this displays the time of regeneration for time clock and delayed units, adjust using the up
and down arrows. A number "2" will appear at the bottom of the display while in this mode.
5. Press status again, this displays the number of pulses/gallon (K factor) for units with a flowmeter only. All other
units will skip this step. Again this setting can be adjusted using the up and down arrows. The recommended K-
Factor for this meter mounted directly to a control valve with the nipple provided is 72. In a straight run of pipe,
as is the case on duplex alternating systems, the recommended K-Factor is 65.
6. Press status again, this displays the backwash time in minutes. The setting can be adjusted using the up and
down arrows. A number "5" will appear at the bottom of the display while in this mode.
7. Press status again, this displays the brine draw/slow rinse time in minutes. The settings can be adjusted using
the up and down arrows. A number "6" will appear at the bottom of the display while in this mode.
8. Press status again, this displays the fast rinse/refill time in minutes. The setting can be adjusted using the up
and down arrows. A number "7" will appear at the bottom of the display while in this mode.
Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
Press to increase or
to decrease
PPrrooggrraammmmiinngg
Press to increase or
to decrease