Service manual

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS
55
The service check mode allows one to view the instantaneous flow rate, the days since the last regenera-
tion, the number of regenerations in the past fourteen days and the gallons remaining. To enter the service
check mode, follow these steps:
1. Press the STATUS key until the display is blank.
Press the UP arrow to access step 11.
2. Push the DOWN arrow. The number 12 will
appear if the flow meter is connected. The display
reads the gallons per minute flow rate.
SSeerrvviiccee CChheecckk
3. Press the DOWN arrow. The number 13A lights
up. The number in the display indicates the num-
ber of regens in the last 14 days.
4. Press the DOWN arrow. The number 13B lights
up. The number in the display indicates the total
number of regenerations since last circuit board
reset.
5. Press the DOWN arrow. The number 14 will light
up. The display will indicate the number of days
since last regeneration.
6. Press the DOWN arrow. The number 15 will be
displayed if the flow meter or Aqua-Sensor
®
is
connected. For the flow meter, display indicates
the gallons remaining before the unit signals for a
regeneration (multiply the displayed number by 10
or 100 depending on dip switch 3 setting). For the
Aqua-Sensor
®
, the display indicates the last slow
rinse time.